October 22, 2024 - October 23, 2024 Sorry. This course is sold out. No further registration possible. Language: EN, Online-Training

Power Quality (Online) 22.10.24.MEL, Melbourne

Timetable: All times are in Australian Eastern Daylight Time (GMT +11)
Description Start End
Day 1: Tuesday 9:00 17:00
Day 2: Wednesday 9:00 17:00

This course provides an introduction to the power quality tools of PowerFactory.

Before registering for this course, prospective attendees should have a fundamental understanding of PowerFactory, including the ability to perform basic calculations (e.g. load-flow) and navigation through the PowerFactory database.

Topics covered include:

CO-1-01 - DIgSILENT Introduction

  • Worldwide Company Overview
  • DIgSILENT Pacific Offices
  • Products
  • History

PF-08-01 - Introduction to Harmonics

  • Principles of harmonic analysis.
  • Harmonic sources and their impact on a power system.
  • Harmonic Analysis Tools in PowerFactory.

PF-08-02 - Harmonic load-flow

  • Definition of harmonic sources in a test network.
  • Assessment of voltage distortion.
  • Verification of distortion limits.
  • Harmonic currents.
  • Bar and distortion diagrams.
  • Waveform plots
  • Modelling of balanced and unbalanced spectrums.
  • Source models in PowerFactory.
  • Calculation options in the Harmonic Load Flow.
  • Power quality indices like HD and THD.
  • Result analysis with harmonic distortion diagrams considering harmonic distortion limits (IEC, IEEE, etc.) and waveform plots.

PF-08-03 - Impedance frequency sweep

  • Definition of self and mutual impedance.
  • Impact of resonances on the network impedance.
  • Frequency response of relevant network components: Cable and overhead lines, network equivalent impedance, loads, transformers.
  • User defined frequency characteristics.

PF-08-04 - Harmonic filters

  • Overview of harmonic filters: single-tuned band pass filter, damped high pass filter,
    C-type filter.
  • Design criteria and filter reports.

PF-08-05 - Harmonic assessment according to IEC 61000-3-6

  • Harmonic load flow calculation according to IEC 61000-3-6.
  • Integer harmonics and non-integer harmonics (interharmonics).
  • Summation laws for harmonics in networks with multiple sources.

PF-08-06 - Flicker assessment according to IEC 61400-21

  • Introduction to flicker and its calculation in PowerFactory.
  • Short and long term flicker severity for continuous and switching operation including voltage change.

PF-08-07 - Envelope curve of the network impedance

  • Simplified representation of the network impedance by an envelope curve to model the first parallel resonance of the network.

PF-08-08 - Network impedance loci

  • Consideration of possible network behaviour in the frequency domain with respect to resistance and reactance of the network impedance for various system states using impedance loci.

PF-08-09 - Voltage unbalance

  • Defining voltage unbalance.
  • Causes and effects of voltage unbalance.
  • Practical definitions of voltage unbalance.
  • Unbalanced system modelling in PowerFactory.

Please note:

  1. Course fee is in AUD and includes GST.
  2. Credit Card payments will incur a 2% surcharge on the course fee. The total amount for credit card transactions will be AUD 2,020.
  3. Participation will only be confirmed once payment has been received by DIgSILENT.
  4. The course is delivered via Microsoft Teams and utilises Microsoft Azure Lab Services training environment.
  5. Course fee includes access to PowerFactory training environment in the Cloud delivered via Microsoft Azure Lab Services.
  6. Participation is contingent on being able to access our training environment, a connection test session will be scheduled prior to date of the seminar.

Full rate AUD 1,980 inclusive of GST

Go back


Upcoming
Training
Courses

There are no items matching your search.

Upcoming Events

Currently there are no events.