Industrial Protection (Online) 01.12.26.PER, Perth
| Description | Start | End |
|---|---|---|
| Day 1: Tuesday | 9 AM | 5 PM |
| Day 2: Wednesday | 9 AM | 5 PM |
Topics covered include:
CO-01-01 - DIgSILENT Introduction
- Global company overview.
- DIgSILENT Pacific offices.
- Products and services offerings.
- PowerFactory development history.
PF-04-02 - Overcurrent protection
- Specifying CBs and fuses’ overcurrent characteristic.
- Adjusting protection settings with simulation.
- Overcurrent protection of motors and LV feeders.
- Verifying coordination with selectivity diagrams.
PF-04-03 - Automated settings calculation
- Calculation of overcurrent settings for LV devices.
- Verification of the calculated settings using the table report.
- Extending the coordination and using equipment specific equations.
- Comparison of existing and new settings using time-overcurrent plots.
PF-04-05 - Distance protection
- Modelling a distance relay in PowerFactory.
- Calculating zone settings with the R-X plot.
- Accounting for influence of the earth factor.
PF-04-07 - Automated coordination calculation
- Checking the existing relay settings
- Automatic calculation of zone settings
- Reporting of results
- Verification of the new settings
PF-04-08 - Differential protection
- Differential protection concept.
- Transformer differential protection.
- Line differential protection.
PF-04-11 - Protection elements
- Protection modelling in PowerFactory.
- Protection single line diagrams.
- Modelling CTs and CT saturation.
- Motor protection characteristic.
PF-04-12 - Fuses graphical modelling
- Capturing fuse characteristics graphically.
- Create a fuse type entry in the project library.
- Testing of fuse model development.
PF-04-13 - Short-circuit trace
- Defining fault events.
- Running a short-circuit trace.
PF-04-14 - Relay model development
- Structuring of the relay model.
- Specifying relay model building blocks.
- Creating a relay type entry in the project library.
- Testing of relay model development.
PF-05-01 - Arc-flash hazard analysis
- Performing arc-flash calculations to IEEE-1584 standard.
- Specifying accessible locations and their parameters.
- Creating an arc-flash report and label database.
Please note:
Full rate AUD 2,178 inclusive of GST
For new users, registering a new user account will not automatically register you for the training course. Please follow the steps below in order to register for the course:
- Create a new user account using the Create New User Account button below;
- Confirm your user account by clicking on the confirmation link received as part of the new user account creation; and lastly,
- Revisit this page to register for the course using the Register For The Training Course button below